Step
| Action
| Value(s)
| Yes
| No
|
1
|
- Turn the ignition switch to the OFF position.
- Disconnect the generator connector.
- Turn the ignition switch to the ON position.
- Connect a scan tool to the Data Link Connector (DLC).
- On the scan tool, perform the following:
| • | Select: Powertrain Control Module (PCM) |
| • | Select: Special Functions. |
| • | Select: Engine Output Controls. |
| • | Select: GEN L Terminal. |
| • | Command the generator ON. |
- Using a DMM, measure the voltage between the generator harness
connector terminal B and ground.
Is the measured voltage within the specified range?
| 5 V
| Go to
Step 2
| Go to
Step 6
|
2
| Using a DMM, measure the voltage between the generator
BATT terminal and ground.
Is the voltage measured within the specified range?
| 9-14 V
| Go to
Step 3
| Go to
Step 9
|
3
|
- Reconnect the generator connector.
- Turn OFF all the accessories.
- Run the engine at idle speed.
- Using DMM, measure the voltage across the battery terminals.
Is the voltage measured within the specified range?
| 13-16 V
| Go to
Step 4
| Go to
Step 10
|
4
| Load test the generator.
Refer to
Charge Indicator Inoperative
.
Does the generator operate properly?
| --
| Go to
Step 5
| Go to
Step 10
|
5
|
- Replace the battery. Refer to
Battery Replacement
.
- Recheck the system.
Is the repair complete?
| --
| Go to
Charging System Check
.
| --
|
6
| Inspect for a poor connection or an open in CKT 225.
Is there a poor connection or open in CKT 225?
| --
| Go to
Step 7
| Go to
Step 8
|
7
|
- Repair a poor connection or an open in CKT 225.
- Recheck the system.
Is the repair complete?
| --
| Go to
Charging System Check
| --
|
8
|
- The Powertrain Control Module (PCM) is not enabling CKT 225,
thus disabling the generator. Refer to
Powertrain Control Module Diagnosis
.
- Recheck the system.
Is the repair complete?
| --
| Go to
Charging System Check
| --
|
9
|
- Repair a poor connection or an open in CKT 2 or the fusible
link to the generator BATT terminal.
- Recheck the system.
Is the repair complete?
| --
| Go to
Charging System Check
| --
|
10
| Replace the generator.
Has the repair been made and the system rechecked?
| --
| Go to
Charging System Check
| --
|