Compressor Control Switches Removal V5 - Conventional Mount
                    
Tools Required
- Recover the refrigerant
 using the J 39500-B 
.
 
- Disconnect the electrical connector from the switch (3
 or 4) in the rear head of the compressor.
 
- Remove the switch retaining ring using the J 5403 
.
 
- Remove the switch (3 or 4) from the compressor.
 
Notice: If the existing switch will be reinstalled in the compressor, a new
O-ring seal must be used and preferably a new retainer should also be used.
A new switch kit has the O-ring and retainer ring included.
- Remove the old O-ring seal from the switch cavity using
the J 9553-01 
.