Compressor Control Switches Install V5 - Conventional Mount
                    Tools Required
J 5403  Snap Ring
 Pliers
- Inspect the switch cavity
and the O-ring groove in the rear head for dirt or foreign material.
 
Clean the cavity and groove as necessary.
- Coat the new O-ring using clean 525 viscosity refrigerant oil.
 
- Install the O-ring into the groove in the switch cavity.
 
- Lubricate the switch housing using clean 525 viscosity refrigerant
oil.
 
- Carefully insert the switch (3 or 4) into the switch cavity
until the switch bottoms in the cavity.
 
- Using the J 5403 
,
install the switch retaining ring with the high point of the curved sides
 adjacent  to the switch housing.
 
- Ensure that the retaining ring is seated in the retaining ring
groove in the switch cavity.
 
- Evacuate and recharge the system.
 
- Perform a leak test. Refer to Compressor Leak
Testing 
 (V5 - Conventional Mount).