Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | Did you review the HVAC system operation and perform the necessary inspections?  | --  | Go to Step 2  | Go to Symptoms  | 
2  | Inspect the fuse block to determine if the HVAC fuse is open. Is the HVAC fuse open?  | --  | Go to Step 3  | Go to Step 6  | 
3  | 
 Does the test lamp light?  | --  | Go to Step 4  | Go to Step 5  | 
4  | Locate and repair a short to ground in CKT 41 (BRN). Refer to Testing for Intermittent Conditions and Poor Connections and Wiring Repairs in Wiring Systems. Is the repair complete?  | --  | Go to Step 13  | --  | 
5  | 
 Does the test lamp light?  | --  | Go to Step 10  | Go to Step 9  | 
6  | 
 Does the test light illuminate?  | --  | Go to Step 7  | Go to Step 10  | 
7  | Use a test lamp to probe between the blower motor connector terminal A and terminal B. Does the test light illuminate?  | --  | Go to Step 8  | Go to Step 11  | 
8  | Replace the blower motor. Refer to Blower Motor and Fan Replacement . Is the repair complete?  | --  | Go to Step 13  | --  | 
9  | Replace the heater-A/C control. Refer to Control Assembly Replacement . Is the repair complete?  | --  | Go to Step 13  | --  | 
10  | 
 Does the test light illuminate?  | --  | Go to Step 11  | Go to Step 12  | 
11  | Replace the blower motor resistor. Refer to Blower Motor Resistor Replacement . Is the repair complete?  | --  | Go to Step 13  | --  | 
12  | Locate and repair a poor connection or an open in CKT 150 (BLK) between the blower motor resistor connector C 1 terminal E and G200. Refer to Testing for Intermittent Conditions and Poor Connections and Wiring Repairs in Wiring Systems. Is the repair complete?  | --  | Go to Step 13  | --  | 
13  | Verify that the system operates properly. Does the system operate properly?  | --  | System OK  | Go to Symptoms  |