Step  | Action  | Value(s)  | Yes  | No  | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1  | Did you review the HVAC system operation and perform the necessary inspections?  | --  | Go to Step 2  | Go to Symptoms  | ||||||||||
2  | 
 
 
 
 
 
 Does the test lamp light for any test?  | --  | Go to Step 3  | Go to Step 6  | ||||||||||
3  | 
 Does the test lamp keep lighted?  | --  | Go to Step 4  | Go to Step 5  | ||||||||||
4  | Locate and repair the short to B+ in the affected circuit: 
 Is the repair complete?  | --  | Go to Step 7  | --  | ||||||||||
5  | Replace the heater-A/C control. Refer to Control Assembly Replacement . Is the repair complete?  | --  | Go to Step 7  | --  | ||||||||||
6  | Replace the blower motor resistor. Refer to Blower Motor Resistor Replacement . Is the repair complete?  | --  | Go to Step 7  | --  | ||||||||||
7  | Verify that the system operates properly. Does the system operate properly?  | --  | System OK  | Go to Symptoms  |