Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | Did you review the HVAC system operation and perform the necessary inspections?  | --  | Go to Step 2  | Go to Symptoms  | 
2  | Check the HVAC fuse in the fuse block. Is the HVAC fuse open?  | --  | Go to Step 3  | Go to Step 4  | 
3  | Locate and repair a short to ground in circuit 41 (BRN). Refer to Testing for Intermittent Conditions and Poor Connections and Wiring Repairs in Wiring Systems.. Is the repair complete?  | --  | Go to Step 6  | --  | 
4  | There is a fault in the vacuum source, vacuum actuators, vacuum hoses to actuators, linkage from actuators to values, or faulty valves. Refer to Vacuum System for further diagnosis. Is the action complete?  | --  | Go to Step 6  | Go to Step 5  | 
5  | Replace the heater-A/C control. Refer to Control Assembly Replacement . Is the repair complete?  | --  | Go to Step 6  | --  | 
6  | Verify that the system operates properly? Does the system operate properly?  | --  | System OK  | Go to Symptoms  |