| Table 1: | Instrument Panel Cluster Scan Tool Data Parameters | 
| Table 2: | Instrument Panel Cluster Scan Tool Output Controls | 
Parameter  | System State  | Expected Value  | Definition  | 
|---|---|---|---|
Operating Conditions: Ignition ON  | |||
Battery Voltage  | --  | Varies  | This displays volts. This is the voltage input supplied to the instrument panel cluster.  | 
Brake Fluid  | --  | OK  | The scan tool displays OK or Low. This is the state of the brake fluid level.  | 
Brake Fluid Switch  | --  | Varies  | This displays volts. This is the voltage status of the brake fluid switch.  | 
DIC Fuel Info.  | --  | Inactive  | The scan tool displays Active or Inactive. This is the state of the DIC Fuel Info. switch.  | 
DIC Information Switch  | --  | Inactive  | The scan tool displays Active or Inactive. This is the state of the DIC Information switch.  | 
DIC Personalization  | --  | Off  | The scan tool displays Active or Inactive. This is the state of the DIC Personalization switch.  | 
End Model Part Number  | --  | Numeric  | This displays the part number of the instrument panel cluster.  | 
Ignition 1 Input  | --  | Active  | The scan tool displays Active or Inactive. This is the state of the Ignition 1 input to the instrument panel cluster.  | 
Ignition Cycle Counter  | --  | Varies  | The scan tool displays counts. This is the number of times the ignition has been cycled from the OFF to ON position.  | 
Odo/Trip Switch  | --  | Inactive  | The scan tool displays Active or Inactive. This is the state of the odometer/trip switch.  | 
Passenger Seatbelt Indicator Commanded  | --  | Off  | This displays On or Off. This is the commanded state of the passenger seatbelt indicator.  | 
Passenger Seatbelt Indicator Status  | --  | Off  | This displays On or Off. This is the state of the passenger seatbelt indicator.  | 
Set/Reset Switch  | --  | Inactive  | The scan tool displays Active or Inactive. This is the state of the set/reset switch.  | 
Washer Fluid Level  | --  | OK  | The scan tool displays OK or Low. This is the state of the washer fluid level.  | 
Scan Tool Output Control  | Description  | 
|---|---|
Dimming  | The IPC dims from 0-100 percent when you select INCREASE or DECREASE by 20 percent increments.  | 
Display Test  | The instrument panel cluster (IPC) illuminates all of the display segments when you select On.  | 
Display(s) Test  | The instrument panel cluster (IPC) sweeps all gages when you select On.  |