| • | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. | 
| • | Review Strategy Based Diagnosis for an overview of the diagnostic approach. | 
| • | Diagnostic Procedure Instructions provides an overview of each diagnostic category. | 
Circuit  | Short to Ground  | Open/High Resistance  | Short to Voltage  | Signal Performance  | 
|---|---|---|---|---|
B+, BCM X2 Terminal 2  | B2652 00  | B2652 00  | --  | --  | 
I/P Lamps Control  | B2652 00  | 2  | 1  | --  | 
1. Interior Backlighting Does Not Dim 2. Interior Backlighting Inoperative  | ||||
The body control module (BCM) supplies a voltage reference through the instrument panel (I/P) dimming voltage reference circuit to the interior lamp dimmer switch, which is part of the headlamp switch. When the dimmer switch is placed in a desired position, reference voltage is applied through the dimmer switch rheostat and the I/P lamps dimmer switch signal circuit to the BCM. The BCM interprets this voltage signal, then applies a pulse width modulated (PWM) voltage through the instrument panel lamp control circuits illuminating the components listed below.
| • | Hazard Switch | 
| • | I/P Cluster | 
| • | Power Window Switches | 
| • | Sunroof Switch | 
| • | Garage Door Opener Transmitter | 
| • | The ignition is ON. | 
| • | The headlamps or park lamps ON. | 
The BCM detects a short to ground on the instrument panel lamps control circuit.
The BCM does not attempt to illuminate the instrument panel lamps.
A history DTC will clear once 100 consecutive malfunction-free ignition cycles have occurred.
Interior Lights Dimming Schematics
Interior Lighting Systems Description and Operation
Control Module References for scan tool information
Ignition ON, command Incandescent Dimming ON with a scan tool. The Incandescent Relay Command parameter should display On and the Incandescent Dimming should illuminate.
| ⇒ | If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance. If the circuit tests normal and the B+ circuit fuse is open, test the control circuits listed below for a short to ground. | 
| • | Instrument panel lamp control circuit terminal 3 X2 | 
| • | Instrument panel lamp control circuit terminal 3 X6 | 
| • | Instrument panel lamp control circuit terminal 3 X2 | 
| • | Instrument panel lamp control circuit terminal 3 X6 | 
| ⇒ | If the DTC resets, test the control circuits for a short to ground. If the circuits test normal, replace the BCM. | 
| ⇒ | If the DTC resets, test or replace the component responsible for setting the DTC. | 
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
| • | Control Module References for BCM replacement, setup, and programming |