Important: When replacing a failed compressor it will be necessary to inspect the orifice tube for material build up. Clean or replace as necessary. Refer to Expansion (Orifice) Tube Replacement .
J 39500-B A/C Refrigerant Recovery, Recycling and Recharging (ACR4) System
Important: When servicing or replacing the compressor, drain and measure the oil from the old compressor. If less than 1 fluid ounce is drained, add 2 ounces to the replacement compressor. If 1 ounce or more is drained, fill the compressor with that amount.
J 39400 Electronic Halogen Leak Detector
Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.
Tighten
Tighten the nuts to 50 N·m (37 lb ft).
Tighten
Tighten the bolt to 50 N·m (37 lb ft).
Important: Inspect the seal washers for damage before reinstalling the A/C lines and hoses.
If any damage is noted during inspection, the suspect seal must be replaced. Flat washer type seals do not require lubrication.
Tighten
Tighten the nut to 30 N·m (22 lb ft).
Tighten
Tighten the bolt to 12 N·m (106 lb in).