Removal Procedure
Important: Clean the tube connections and surrounding areas before disconnecting in order
  to avoid possible evaporative emission (EVAP) system contamination.
- Disconnect the EVAP tube from the EVAP canister purge solenoid.
 
| •  | Push the large size white retainer portion in. | 
 
| •  | Push down, while pulling up slightly in order to disengage the tube. | 
 
- Disconnect the EVAP tube from the chassis EVAP pipe.
 
| •  | Push the large size white retainer portion in. | 
 
| •  | Push down, while pulling up slightly in order the disengage the tube. | 
 
- Remove the EVAP tube.
 
- Cap the EVAP canister purge solenoid and the EVAP chassis pipe in order
  to prevent possible EVAP system contamination.
 
Installation Procedure
- Remove the caps from the EVAP canister   purge  solenoid and the EVAP chassis
pipe.
 
- Install the EVAP tube.
 
- Connect the EVAP tube to the EVAP chassis pipe.
 
- Connect the EVAP tube to the EVAP canister purge solenoid.