Removal Procedure
- Remove the HVAC control module. Refer to
HVAC Module Assembly Replacement
.
- Remove the LH temperature door electric actuator. Refer to
Air Temperature Actuator Replacement - Right Side
in
Manual HVAC Systems.
- Remove the RH temperature door electric actuator. Refer to
Air Temperature Actuator Replacement - Left Side
in
Manual HVAC Systems .
- Remove the recirculation
housing retaining screws (1).
- Remove the recirculation housing (2).
- Remove the HVAC control module upper mounting screws.
- Release the retaining
tab (1) and separate the upper and lower control module halves.
- Remove the HVAC control
module seal that is located between the upper and lower cases.
Start to remove the control module case seal (blower motor side of case)
seal (2) from the lower control module case at the position shown (1).
Important: The LH and RH temperature doors separate in the center.
- Remove the temperature doors (1,2).
Carefully pull the temperature doors apart in the center to remove the
temperature doors from the HVAC control module case.
Installation Procedure
Important: The LH and RH temperature doors pivot in the center.
- Install the temperature doors (1,2).
Carefully align the temperature doors into the HVAC control module case.
- Install the new case seal
(2) into the HVAC control module case (1).
- Align and install the
upper control module case to the lower control module case.
Align and secure the retaining tab (1) on the upper control module case
to the retaining slot on the lower control module case.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the HVAC
control module upper mounting screws.
Tighten
Tighten the HVAC control module upper mounting screws to 1.5 N·m
(13 lb in).
- Install the recirculation
housing (2).
- Install the recirculation housing retaining screws (1).
Tighten
Tighten the recirculation housing screws to 1.5 N·m (13 lb in).
- Install the LH temperature door electric actuator. Refer to
Air Temperature Actuator Replacement - Right Side
in
Manual HVAC Systems.
- Install the RH temperature door electric actuator. Refer to
Air Temperature Actuator Replacement - Left Side
in
Manual HVAC Systems.
- Install the HVAC control module. Refer to
HVAC Module Assembly Replacement
.