Removal Procedure
- Remove the right instrument panel insulator panel. Refer to 
Instrument Panel Insulator Replacement 
 in Instrument Panel,
Gauges and Console.
 
- Remove the instrument panel compartment screws and compartment.
 
- Disconnect the vacuum
line from defroster actuator.
 
- Rotate the defroster door lever fully rearward (counterclockwise),
then carefully insert a screw driver between the bottom of the defrost door
   lever and the protruding wall of the HVAC module case below the door lever
   in order to keep the door lever in place.
 
- Remove the defroster actuator.
 
Installation Procedure
- Install the defroster actuator.
 
- Carefully rotate rearward and downward to align actuator slots
with HVAC module case and push the vacuum actuator toward the HVAC module
   to secure the retaining tab.
 
- Connect the vacuum line
to defroster actuator.
 
- Install the instrument compartment and screws. Refer to 
Instrument Panel Insulator Replacement 
 in Instrument Panel,
Gauges and Console.
 
- Install the right instrument insulator panel.