Use the Scan Tool Data Display Values and Definitions Information
in order to assist in diagnosing the Instrument Panel Integration Module (IPM)
  problems. Compare the vehicles actual scan tool data with the typical data
  display value table information. Use the data information in order to aid
  in understanding the nature of the problem when the vehicle does not match
  with the typical data display values.
The scan tool data values were taken from a known good vehicle under
the following conditions:
|     •  | The ignition switch is in the ON position. | 
 
|     •  | The engine is running at idle. | 
 
|     •  | The vehicle is in PARK. | 
 
|     •  | The windows are closed. | 
 
|     •  | The A/C is ON, in UPPER mode. | 
 
|     •  | The ambient air temperatures are at 22-27°C (70-80°F). | 
 
The HVAC Scan Tool Data Definitions contains a brief description of
all HVAC related parameters available on the scan tool. The list is in alphabetical
  order. A given parameter may appear in any one of the data lists. In some
  cases, the parameter may appear more than once or in more than one data
list   in order to group certain related parameters together.
Auto Button: The scan tool displays Off or On. When the AUTO button is pressed
the scan tool displays On. When released, the scan tool displays Off.
Calibration ID: The scan tool displays the Calibration ID number for service identification.
Desired Blower Mtr Speed: The scan tool displays 0-111 Counts. When the blower
motor is OFF, the scan tool displays 0 Counts. When the blower motor
  controls are  placed in the maximum speed setting, the scan tool displays
  111 Counts.
Driver Temp Dial: The scan tool displays 15° to 32°C (59° to 89°F).
The temperature displayed represents the desired system discharge temperature
  selected by the driver.
Driver Temp Down Button: The scan tool displays Off or On. When the DRIVER TEMP DOWN button
is pressed the scan tool displays On. When released, the scan tool displays
  Off.
Driver Temp Up Button: The scan tool displays Off or On. When the DRIVER TEMP UP button
is pressed the scan tool displays On. When released, the scan tool displays
  Off.
Dual Button: The scan tool displays Off or On. When the DUAL button is pressed
the scan tool displays On. When released, the scan tool displays Off.
Fan Down Button: The scan tool displays Off or On. When the BLOWER SPEED CONTROL
DOWN button is pressed the scan tool displays On. When released, the scan
   tool displays Off.
Fan Up Button: The scan tool displays Off or On. When the BLOWER SPEED CONTROL
DOWN button is pressed the scan tool displays On. When released, the scan
  tool  displays Off.
Front Defrost Button: The scan tool displays Off or On. When the FRONTDEFROST button
is pressed the scan tool displays On. When released, the scan tool displays
  Off.
Inside Temp Sensor: The scan tool displays 0-5.0 Volts. The voltage displayed
represents the inside air temperature sensor signal to the HVAC control module.
LH Mix Mtr Position Feedback: The scan tool displays 0-255 Counts. The counts displayed
represent the position of the left air temperature actuator.
LH Mix Mtr Position Requested: The scan tool displays 0-255 Counts. The counts displayed
represent the commanded position of the left air temperature actuator.
Mix Motor State: When the left and right air temperature actuators are operating
properly, the scan tool displays Normal.
Mode Down Button: The scan tool displays Off or On. When the MODE DOWN button is
pressed the scan tool displays On. When released, the scan tool displays Off.
Mode Up Button: The scan tool displays Off or On. When the MODE UP button is pressed
the scan tool displays On. When released, the scan tool displays Off.
Off Button: The scan tool displays Off or On. When the OFF button is pressed
the scan tool displays On. When released, the scan tool displays Off.
Outside Temp Sensor: The scan tool displays 0-5.0 Volts. The voltage displayed
represents the value of the outside air temperature sensor signal.
Passenger Temp Dial: The scan tool displays 80-176 Counts. The counts displayed
represent the position of the PASSENGER temperature dial, 80 being the coolest
   setting and 176 being the warmest.
Passenger Temp Down Button: The scan tool displays Off or On. When the PASSENGER TEMP DOWN
button is pressed the scan tool displays On. When released, the scan tool
  displays Off.
Passenger Temp Down Button: The scan tool displays Off or On. When the PASSENGER TEMP UP button
is pressed the scan tool displays On. When released, the scan tool displays
  Off.
PCM -- A/C Relay Command: The scan tool displays ON or OFF. ON is displayed when the PCM
has energized the A/C compressor clutch relay.
PCM -- Engine Data 2 -- A/C High Side Pressure: The scan tool displays -103 to +3119 kPa (-14
to +452 psi). This parameter represents the A/C refrigerant pressure
  sensor voltage signal converted to pressure.
PCM -- Engine Data 2 -- A/C High Side Pressure: The scan tool displays 0.00-5.00 Volts. This parameter
represents the A/C refrigerant pressure sensor signal. 
PCM -- Engine Data 2 -- A/C Off for WOT: The scan tool displays Yes or No. Yes is displayed when the PCM
de-energizes the A/C compressor clutch relay to reduce engine load during
  wide open throttle.
PCM -- Engine Data 2 --  A/C Pressure Disable: The scan tool displays Yes or No. Yes is displayed when the system
pressure exceeds 2968 kPa (430 psi).
PCM -- Engine Data 2  -- A/C Request Signal: The scan tool displays Yes or No. Yes is displayed when the HVAC
Control Module is requesting A/C system operation.
PCM -- Output Driver Data -- A/C Relay Circuit Status: The scan tool displays OK or Fault. Fault is displayed when an
open or short is detected in the A/C compressor clutch relay ground circuit.
Rear Defrost Button: The scan tool displays Off or On. When the REAR DEFROST button
is pressed the scan tool displays On. When released, the scan tool displays
  Off.
Recirculate Button: The scan tool displays Off or On. When the RECIRCULATION button
is pressed the scan tool displays On. When released, the scan tool displays
  Off.
RH Mix Mtr Position Feedback: The scan tool displays 0-255 Counts. The counts displayed
represent the position of the right air temperature actuator.
RH Mix Mtr Position Requested: The scan tool displays 0-226 Counts. The counts displayed
represent the commanded position of the right air temperature actuator.
Rom ID: The scan tool displays the Rom ID number for service identification.
ROM Part Number: The scan tool displays the ROM part number for service identification.
Sun Load Sensor: The scan tool displays 0-5.0 Volts. The voltage displayed
represents the value of the sunload sensor signal.
Vacuum Solenoid 1: The scan tool displays On or Off. When Vacuum Solenoid 1 is energized
the scan tool displays On.  When the solenoid is de-energized the  scan tool
  displays Off.
Vacuum Solenoid 2: The scan tool displays On or Off. When Vacuum Solenoid 2 is energized
the scan tool displays On.  When the solenoid is de-energized the   scan tool
  displays Off.
Vacuum Solenoid 3: The scan tool displays On or Off. When Vacuum Solenoid 3 is energized
the scan tool displays On. When the solenoid is de-energized the  scan tool
  displays Off.
Vacuum Solenoid 4: The scan tool displays On or Off. When Vacuum Solenoid 4 is energized
the scan tool displays On. When the solenoid is  de-energized the  scan tool
  displays Off, and the Air Inlet Valve Vacuum Actuator  is in the  outside
  air position.
Vacuum Solenoid 5: The scan tool displays On or Off. When Vacuum Solenoid 5 is energized
the scan tool displays On. When the solenoid is de-energized the  scan tool
  displays Off.