Instrument Panel Inflatable Restraint Module Replacement Rendezvous
                    
Removal Procedure
Caution: Refer to SIR Inflator Module Handling and Storage Caution in the Preface section.
Caution: Refer to SIR Caution in the Preface section.
Caution: A deployed dual stage inflator module will look the same whether one  or both
 stages were used. Always assume a deployed dual stage inflator module  has an active
 stage 2. Improper handling or servicing can activate the inflator  module and cause
 personal injury.
- Disable the SIR system. Refer to 
SIR Disabling and Enabling 
.
 
- Remove the trim pad from the instrument panel (I/P). Refer to 
Instrument Panel Assembly Replacement 
.
 
- Disconnect the inflator module connector.
 
- Remove the 4 bolts from the inflator restraint module bracket.
 
- Remove the inflatable restraint module from the I/P.
 
- Fully deploy the module before disposal. If the module was replaced under warranty, fully deploy and dispose of the module after the required retention period. Refer to 
Inflator Module Handling and Scrapping 
.
 
Installation Procedure
- Install the inflatable restraint module to the instrument panel (I/P).
 
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the I/P bolts to the inflatable restraint module.
 
Tighten
Tighten the bolts to 10 N·m (89 lb in).
- Connect the inflatable module connector.
 
- Install the trim pad to the I/P. Refer to 
Instrument Panel Assembly Replacement 
.
 
- Enable the SIR system. Refer to 
SIR Disabling and Enabling 
.
 
                            Instrument Panel Inflatable Restraint Module Replacement Aztek
                    
Removal Procedure
Caution: Refer to SIR Caution in the Preface section.
Caution: Refer to SIR Inflator Module Handling and Storage Caution in the Preface section.
- Disable the SIR system. Refer to 
SIR Disabling and Enabling 
.
 
- Remove the instrument panel (I/P) compartment. Refer to 
Instrument Panel Compartment Replacement 
 in Instrument Panel, Gages, and Console.
 
- Disconnect the inflator module connector.
 
- Remove the I/P nuts from the inflator restraint module.
 
- Remove the inflatable restraint module (1) from the I/P.
 
- Fully deploy the module before disposal. If the module was replaced under warranty, fully deploy and dispose of the module after the required retention period. Refer to 
Inflator Module Handling and Scrapping 
.
 
Installation Procedure
- Install the inflatable restraint module (1) to the I/P.
 
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the I/P nuts to the inflatable restraint module.
 
Tighten
Tighten the nuts to 10 N·m (89 lb in).
- Connect the inflatable restraint module connector.
 
- Install the instrument panel (I/P) compartment. Refer to 
Instrument Panel Compartment Replacement 
 in Instrument Panel, Gages, and Console.
 
- Enable the SIR system. Refer to 
SIR Disabling and Enabling 
.