Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | Perform the Audible Warnings System Check before processing. Is the system check complete?  | --  | Go to Step 2  | |
2  | 
 Is the measured resistance less than the specified value?  | 5 ohms  | Go to Step 4  | Go to Step 3  | 
3  | Replace the mall module. Is the repair complete?  | --  | --  | |
4  | Does the keyless entry work?  | --  | Go to Step 5  | Go to Keyless Entry for Diagnosis  | 
5  | Inspect CKT 653 (DK BLU/WHT) for an open. Is the circuit OK?  | --  | Go to Step 10  | Go to Step 6  | 
6  | 
 Is the measured resistance less than the specified value?  | 5 ohms  | Go to Step 9  | Go to Step 7  | 
7  | Inspect the RFA module connector for proper terminal contact. Is the contact OK?  | --  | Go to Step 8  | --  | 
8  | Replace the RFA module. Is the repair complete?  | --  | --  | |
9  | 
 Is the wiring OK?  | --  | Go to Step 10  | |
10  | Repair the open. Is the repair complete?  | --  | --  |