Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | Did you perform the Instrument Cluster System Check?  | --  | Go to Step 2  | |
2  | 
 Is the voltage equal to the specified value?  | 12 V  | Go to Step 5  | Go to Step 3  | 
3  | Inspect CKT 748 (LT GRN/BLK) for a short to ground. Is CKT 748 OK?  | --  | Go to Step 6  | Go to Step 4  | 
4  | Repair a short to ground in CKT 748. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair?  | --  | Go to Step 6  | --  | 
5  | Measure the voltage between the connector C and the connector D. Is the voltage equal to the specified value?  | 12 V  | Go to Step 10  | Go to Step 8  | 
6  | Inspect the instrument cluster connector C2 terminal B5 for proper terminal contact. Is the terminal contact OK?  | --  | Go to Step 7  | Go to Step 12  | 
7  | Replace the instrument cluster. Refer to Instrument Cluster Replacement or Instrument Cluster Replacement . Did you complete the repair?  | --  | --  | |
8  | Inspect CKT 151 (BLK/WHT) for an open. Is CKT 151 OK?  | --  | Go to Step 9  | |
9  | Repair the open in CKT 151. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair?  | --  | --  | |
10  | Inspect the suspect rear door latch assembly connector for proper terminal contact. Is the terminal contact OK?  | --  | Go to Step 11  | Go to Step 12  | 
11  | Replace the suspect rear door latch assembly. Refer to Rear Side Door Lock Actuator Replacement in Doors. Did you complete the repair?  | --  | --  | |
12  | Repair the faulty connector. Refer to Connector Repairs in Wiring Systems. Did you complete the repair?  | --  | --  |