Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | Did you perform the Horns System Check?  | --  | Go to Step 2  | Go to Horns System Check  | 
2  | Disconnect the horn relay. Are the horns on?  | --  | Go to Step 4  | Go to Step 3  | 
3  | Connect a test lamp between relay terminal 86 and terminal 85. Does the test lamp light?  | --  | Go to Step 6  | Go to Step 5  | 
4  | Repair CKT 29 (DK GRN) for a short to B+. Is the repair complete?  | --  | Go to Horns System Check  | --  | 
5  | Replace the horn relay. Is the repair complete?  | --  | Go to Horns System Check  | --  | 
6  | 
 Are the horns on?  | --  | Go to Step 7  | Go to Step 8  | 
7  | Repair CKT 28 (BLK) for a short to ground. Is the repair complete?  | --  | Go to Horns System Check  | --  | 
8  | Replace the horn switch. Is the repair complete?  | --  | Go to Horns System Check  | --  |