The HVAC control assembly receives a 12 volt signal through circuit 835 from the HVAC programmer.
| • | The ignition is ON. | 
| • | The circuit is open or shorted. | 
| • | Code DTC B1035 is set. | 
| • | The HVAC control assembly will not operate. | 
| • | Using a Scan Tool . | 
| • | A history DTC will clear when 40 consecutive ignition cycles have occurred without a malfunction. | 
Step  | Action  | Value(s)  | Yes  | No  | ||||
|---|---|---|---|---|---|---|---|---|
1  | 
 Does the Scan Tool display one of the following conditions? 
 
  | --  | Go to Scan Tool Does Not Communicate with E and C Data Line in Data Link Communications.  | Go to Step 2  | ||||
2  | Observe the Scan Tool display. Does the Scan Tool identify any components?  | --  | Go to Step 3  | Go to Scan Tool Does Not Communicate with E and C Data Line In Data Link Communications  | ||||
3  | Observe the Scan Tool display. Does the Scan Tool identify the HVAC control assembly?  | --  | Go to Step 5  | Go to Step 4  | ||||
4  | 
 Does proper terminal contact exist?  | Go to Step 6  | Go to Step 7  | |||||
5  | 
 Is continuity present?  | --  | Go to Step 10  | Go to Step 11  | ||||
6  | 
 Refer to Measuring Voltage in Wiring Systems. Is battery voltage present?  | --  | Go to Step 9  | Go to Step 8  | ||||
7  | Repair the faulty terminal contact. Refer to Repairing Connector Terminals in Wiring Systems. Is the repair complete?  | --  | System OK  | --  | ||||
8  | Replace the HVAC control assembly. Refer to Control Assembly Replacement . Is the repair complete?  | --  | System OK  | --  | ||||
9  | Repair the open in CKT 835. Refer to Wiring Repairs in Wiring Systems. Is the repair complete?  | --  | System OK  | --  | ||||
10  | Inspect terminal C4 of the programmer harness connector and terminal B1 of the HVAC control assembly for proper terminal contact. Does proper terminal contact exist?  | --  | Go to Step 12  | Go to Step 13  | ||||
11  | Repair the open in CKT 835. Refer to Wiring Repairs in Wiring Systems. Is the repair complete?  | --  | System OK  | --  | ||||
12  | Replace the HVAC programmer. Refer to Programmer Replacement . Is the repair complete?  | --  | System OK  | --  | ||||
13  | Repair the faulty terminal contact. Refer to Repairing Connector Terminals in Wiring Systems. Is the repair complete?  | --  | System OK  | --  |