Step  | Action  | Value(s)  | Yes  | No  | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
1  | Did you perform the Instrument Cluster Diagnostic System Check?  | --  | Go to Step 2  | |||||||||
2  | Inspect the following circuits for a short to ground or B+: 
 
 
 
 Was a fault found in any of the wiring?  | --  | Go to Step 3  | Go to Step 4  | ||||||||
3  | Repair the wiring. Is the repair complete?  | --  | --  | |||||||||
4  | Inspect the following terminals for proper terminal contact: 
 
 
 
 Were the terminal contacts OK?  | --  | Go to Step 6  | Go to Step 5  | ||||||||
5  | Repair the poor terminal connection. Is the repair complete?  | --  | --  | |||||||||
6  | Replace the instrument cluster. Refer to Instrument Cluster Replacement . Is the repair complete?  | --  | --  |