Calibration Criteria
Brake pedal position sensor calibration must be preformed after the brake pedal
position sensor or electronic brake control module (EBCM) have been serviced. The
calibration procedure will set the brake pedal position sensor "home"
value. This value is used by the EBCM to determine the action of the driver applying
the brake system and to provide this information to the vehicle subsystems via the
class II communication bus.
Calibration Procedure
• | Turn ON the ignition, with the engine OFF. |
• | Select DRP/ABS/TCS/VSES. |
• | Select Special Functions. |
• | Select the BPP Sensor Calibration and follow the directions
displayed on the screen. |