- Use a small screwdriver in order to
disconnect the electrical connectors  from the following   parts:
 
| •  | 1-2 shift solenoid valve (909) | 
 
| •  | 2-3 shift solenoid valve (910) | 
 
| •  | Internal mode switch (IMS) (942) | 
 
- Remove the 3, 10 mm
 bolts (534) from the channel plate side.
 
- Remove the 6, 10 mm bolts (534, 951, 952, 954) 
from the accumulator housing.
 
Important: There are 4 checkballs (65) and a spring (971) under 
the accumulator housing (944).
- Remove the accumulator housing (944) from the channel plate.
 
- Remove the 4 checkballs (65)
and the spring (971) from  the channel plate.
 
- In order to disconnect  the manual valve
and link assembly (916) from the internal mode switch (IMS) (942),
 rotate the manual   valve and link assembly (916) toward the IMS (942).
 
- Turn the manual valve  link 90 degrees
and rotate the manual valve and link assembly (916)  away from the
IMS (942).
 
- Remove the 3, 8 mm bolts (939)
from the internal mode  switch (IMS) (942).
 
- Remove the IMS (942).
 
- Remove the 15, 10 mm bolts (938,
940, 941) from the lower control valve body.
 
- Remove the solenoid valve fluid filter retainer (981).
 
- Remove the lower control valve assembly (903) from the
 channel plate.
 
- Remove the 4 checkballs (65).
 
- Remove the spacer plate and gasket assembly (935) from
 the channel plate (900).