Engine Coolant Outlet Pipe Replacement LP1, LY7
                    Tools Required
J 38185 
 Hose Clamp Pliers
Removal Procedure
- Drain the cooling system. Refer to 
Cooling System Draining and Filling
 .
 
- Position the 
J 38185 
 to the clamp in order to remove
the radiator inlet hose (1) from the coolant outlet pipe.
 
- Remove the bolt (2) securing the following to the cylinder head:
 
| •  | The oil level indicator tube (4) | 
 
| •  | The coolant outlet pipe (3) | 
 
| •  | The engine front lift bracket (1) | 
 
- Remove the coolant outlet pipe (3) from the thermostat housing.
 
- Remove the O-ring seals from the coolant outlet pipe.
 
Discard the O-rings.
Installation Procedure
- Lubricate 2 new O-ring seals with coolant.
 
Important: Ensure the O-rings are not twisted.
- Install the new O-ring seals around the coolant outlet pipe grooves.
 
- Insert the coolant outlet pipe (3) into the thermostat housing.
 
Notice: Refer to Fastener Notice in the Preface section.
- Install the bolt (2) securing the following to the cylinder head:
 
| •  | The oil level indicator tube (4) | 
 
| •  | The coolant outlet pipe (3) | 
 
| •  | The engine front lift bracket (1) | 
 
Tighten
Tighten the oil level indicator tube bolt to 20 N·m (15 lb ft).
- Position the 
J 38185 
 to the clamp in order to connect
the radiator inlet hose (1) to the coolant outlet pipe.
 
- Fill the cooling system. Refer to 
Cooling System Draining and Filling
 .