Removal Procedure
- Turn the ignition OFF.
 
- Remove the positive crankcase ventilation (PCV) hose from the air cleaner duct resonator.
 
- Loosen the air cleaner duct clamps.
 
- Remove the air cleaner duct.
 
Installation Procedure
- Install the air cleaner intake duct.
 
- Install the PCV hose to the intake duct resonator.
 
Notice: Refer to Fastener Notice in the Preface section.
- Tighten the air cleaner duct clamps.
 
Tighten
| •  | Tighten the air cleaner duct clamp at the mass air flow (MAF) sensor to 4 N·m (35 lb in). | 
 
| •  | Tighten the air cleaner duct clamp at the throttle body to 7 N·m (35 lb in). |