Important: 
   •  All gasket surfaces should be free of oil and other foreign material during assembly.    •  DO NOT reuse the valve rocker arm cover gasket.    •  The valve rocker arm cover bolt grommets may be reused.    •  If the oil fill tube has been removed from the rocker arm cover, install a NEW fill tube during assembly. 
Rotate the tube clockwise until locked in the proper position.
Rotate the cap clockwise until locked in the proper position.
Notice: Refer to Fastener Notice in the Preface section.
Tighten
Tighten the valve rocker arm cover bolts to 12 N·m (106 lb in).