Step
| Action
| Value(s)
| Yes
| No
|
1
| Was the Interior Lights System Check performed?
| --
|
Go to Step 2
| Go to
Interior Lamps System Check
.
|
2
|
- Disconnect the dome and reading lamps connector.
- Turn the ignition switch to the ON position.
- Use the DMM to measure the voltage between terminal 3 of the dome
and reading lamps connector and a known good ground.
Is the measured voltage within the specified value?
| B+
|
Go to Step 4
|
Go to Step
3
|
3
|
- Locate an open or a high resistance in circuit AP882.
- Repair the open or the high resistance in circuit AP882.
Is the repair complete?
| --
|
Go to Step
7
| --
|
4
| Use the DMM to measure the resistance between terminal 2 of the dome
and reading lamps connector and a known good ground.
Is the measured resistance within the specified value?
| Less than 5 ohms
|
Go to Step 6
|
Go to Step 5
|
5
|
- Locate an open or a high resistance in circuit F901.
- Repair the open or the high resistance in circuit F901.
Is the repair complete?
| --
|
Go to Step
7
| --
|
6
| Replace the reading lamps. Refer to
Dome Lamp Replacement
in Lighting Systems.
Is the replacement complete?
| --
|
Go to Step
7
| --
|
7
|
- Connect all connectors and components that were disconnected.
- Verify that the reading lamps operate properly.
Do the reading lamps operate properly?
| --
| Go to
Interior Lamps System Check
.
|
Go to Step
1
|