| • | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
| • | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
| • | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
|---|---|---|---|---|
Clock Battery Positive Voltage Circuit | 1 | 1 | -- | -- |
Clock Ground Circuit | -- | 1 | -- | -- |
1. Clock Malfunction | ||||
The instrument panel is equipped with an analog clock. The analog clock utilizes the clock battery positive voltage circuit and the clock ground circuit to operate. An open circuit condition, a high resistance or a short to ground in the battery positive voltage circuit or the ground circuit will cause the clock not to operate properly.
| ⇒ | If greater than the specified value, test the ground circuit for an open/high resistance. |
| ⇒ | If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance. If all circuits test normal, replace the clock. |