The inside air temperature sensor is a thermistor that controls the signal voltage to the heater and A/C programmer. The heater and A/C programmer supplies voltage on CKT 734. When the sensor is cold, the following conditions exist:
| • | The resistance is high. | 
| • | The heater and A/C programmer reads a high signal voltage at pin D9. | 
As the sensor warms, the following actions occur:
| • | The resistance decreases. | 
| • | The signal voltage is pulled low through the sensor ground, CKT 407. | 
The signal voltage varies between 5 V (open circuit) and 0 V (short circuit).
| • | Turn the ignition to the ON position. | 
| • | The ambient air temperature reads above -29°C (-20°F). | 
| • | DTCs B1310 or B1311 are not set. | 
A substitute temperature reading of 24°C (75°F) is used in order to continue the operation. As a result, the internal temperature may be overly warm or overly cold.
If an intermittent DTC B1316 is set, use a Scan Tool in order to select the following settings:
| • | Data list | 
| • | Open/shorts data | 
| • | Observe the reading | 
Manipulate the wiring while observing the Scan Tool . If a failure is induced, the reading will jump. Inspect for the following conditions:
| • | Faulty terminal contact | 
| • | An obstructed or defective sensor | 
The Scan Tool displays the inside air temperature. Jumping the harness connector determines if the wiring or the sensor is the cause.
Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
Did you perform the Diagnostic System Check?  | --  | Go to Step 2  | Go to Diagnostic System Check  | |
2  | 
 Did the DTC change from B1316 to B1317?  | --  | Go to Step 4  | Go to Step 3  | 
3  | Measure the voltage at terminal B. Refer to Measuring Voltage in Wiring Systems. Is the measured voltage approximately equal to the specified value?  | 5 V  | Go to Step 6  | Go to Step 5  | 
4  | 
 Did you complete the repair?  | --  | System OK  | --  | 
5  | Measure the voltage at terminal D9 of the heater and A/C programmer. Refer to Measuring Voltage in Wiring Systems. Is the measured voltage approximately equal to the specified value?  | 5 V  | Go to Step 8  | Go to Step 7  | 
6  | 
 Did you complete the repair?  | --  | Go to Diagnostic System Check  | --  | 
7  | 
 Did you complete the repair?  | --  | Go to Diagnostic System Check  | --  | 
8  | Measure the voltage at cavity C of C205. Refer to Measuring Voltage in Wiring Systems. Is the measured voltage approximately equal to the specified value?  | 5 V  | Go to Step 10  | Go to Step 9  | 
9  | 
 Did you complete the repair?  | --  | Go to Diagnostic System Check  | --  | 
10  | 
 Did you complete the repair?  | --  | Go to Diagnostic System Check  | --  |