The remote function actuator (RFA) module performs internal tests on the EEPROM each time the RFA module performs a write function to a memory address in the EEPROM.
The remote function actuator (RFA) module reads back the data that has been written and compares the data. If the data does not match after 3 consecutive write and verify attempts, the RFA module will indicate a write malfunction as current.
| • | The remote function actuator (RFA) module stores a DTC B1007 in memory. | 
| • | No driver warning message is displayed for this DTC. | 
The remote function actuator (RFA) module no longer detects an internal write malfunction.
The EEPROM cannot be removed from the remote function actuator (RFA) module.
Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | Was the Remote Keyless Entry Diagnostic System Check performed?  | --  | ||
2  | 
 Is DTC B1007 still present?  | --  | ||
3  | Replace the remote function actuator (RFA) module. Refer to Remote Control Door Lock Receiver Replacement . Is the repair complete?  | --  | --  |