Removal Procedure
Warning: Refer to SIR Warning in the Preface section.
- Disable the SIR system. Refer to 
SIR Disabling and Enabling.
 
- Remove the knee bolster. Refer to 
Knee Bolster Replacement.
 
- Disconnect the electrical connector from the telescope actuator assembly.
 
- Remove the fastener bolt (2) from the telescope actuator assembly.
 
- Remove the telescope actuator assembly (1) from the steering column.
 
- Remove the potentiometer housing  (3) from the telescope actuator assembly.
 
- Disconnect the telescope cable from the telescope actuator assembly.
 
Installation Procedure
- Install the white end of the telescope actuator cable assembly to the steering column.
 
- Install the black end of the telescope actuator cable to the telescope actuator assembly.
 
- Install the potentiometer housing (3) to the telescope actuator assembly (1).
 
- Install the telescope actuator assembly.
 
Caution: Refer to Fastener Caution in the Preface section.
- Install the retaining bolt (2) to the telescope actuator assembly.
 
Tighten
Tighten the bolts to 5 N·m (44 lb in).
- Connect the electrical connector to the telescope assembly actuator.
 
- Install the knee bolsters. Refer to 
Knee Bolster Replacement.
 
- Enable the SIR system. Refer to 
SIR Disabling and Enabling.