Special Tools
- Attach the 
J 22124-91 
 to the air dryer.
 
- Attach the 
J 22124-B 
 to the 
J 22124-91 
 with the toggle valve on the opposite side of the air compressor. Close the toggle valve.
 
- Apply air pressure at the schrader valve. Pressurize until the 
J 22124-B 
 reads 690 kPa (100 psi).
 
- Check the following areas using soap bubbles:
 
| •  | Air dryer to compressor head O-ring | 
 
| •  | Air compressor head gasket | 
 
| •  | Air compressor head cover--If necessary, tighten the cover bolts to 5.6 N·m (50 lb in). | 
 
If a leak is found, replace the air compressor. Refer to 
Air Compressor Replacement
 .