Removal Procedure
- Recover the refrigerant. Refer to Refrigerant Recovery and Recharging
.
 
- Disconnect the electrical connector from
the sensor.
 
- Unscrew the sensor from the refrigerant line.
 
Installation Procedure
- Install the sensor to the refrigerant line.
 
- Connect the electrical connector to the
sensor.
 
- Evacuate and charge the system. Refer to Refrigerant Recovery and Recharging
.