Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | Was Instrument Cluster System Check performed?  | --  | Go to Step 2  | |
2  | 
 Does the DIC change ?  | --  | Go to Step 3  | |
3  | 
 Does the INFO Up Switch input toggle from ON to OFF when button is pressed?  | --  | Go to Step 11  | Go to Step 4  | 
4  | Does the INFO down button work?  | --  | Go to Step 5  | Go to Step 8  | 
5  | 
 When the jumper is added and removed does the scan tool INFO UP switch input toggle ON/OFF ?  | --  | Go to Step 10  | Go to Step 6  | 
6  | Check for CKT 1544 (ORN) for an open or short to ground. Was there a problem with CKT 1544?  | --  | Go to Step 7  | Go to Step 11  | 
7  | Repair CKT 1544 (ORN). Is the repair complete?  | --  | --  | |
8  | Check for CKT 451 (BLK/WHT) for an open. Was there a problem with CKT 451?  | --  | Go to Step 9  | Go to Step 10  | 
9  | Repair CKT 451 (BLK/WHT). Is the repair complete?  | --  | --  | |
10  | Replace the RH IPC control (DIC) switch. Refer to Driver Information Display Switch Replacement . Is the repair complete?  | --  | --  | |
11  | Replace the Instrument Cluster (IPC). Refer to Instrument Cluster Replacement . Is the Instrument Cluster (IPC) replacement complete?  | --  | --  |