Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | 
 Does the voltage equal the specified value?  | 6 V  | Go to Step 2  | Go to Step 4  | 
2  | Reconnect the blower motor connector. Does the blower motor run on high speed?  | --  | Go to Step 3  | System OK  | 
3  | Replace the blower motor. Refer to Blower Motor and Fan Replacement in Heating, Ventilation and Air Conditioning. Is the repair complete?  | --  | System OK  | --  | 
4  | Measure the voltage at terminal C of the blower control module input. Does the voltage equal the specified value?  | 4-5 V  | Go to Step 5  | Go to Step 6  | 
5  | Replace the blower control module. Refer to Blower Motor Control Module Replacement in Heating, Ventilation and Air Conditioning. Is the repair complete?  | --  | System OK  | --  | 
6  | Replace the instrument panel integration module. Refer to Instrument Panel Module Replacement in Body Control Systems. Is the repair complete?  | --  | System OK  | --  |