Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | Has the diagnostic system check been performed?  | --  | Go to Step 2  | Go to Diagnostic System Check  | 
2  | 
 Are any HVAC DTCs present?  | --  | Go to Step 3  | |
3  | Using the Scan Tool view A/C system pressures. Is the A/C system pressure normal?  | --  | Go to Step 4  | Go to Cooling Insufficient - Air Conditioning (A/C) Inoperative  | 
4  | 
 Is the right center outlet air temperature cooler than the left outlet?  | --  | Go to Step 5  | Go to Step 6  | 
5  | 
 Is the right center outlet air temperature warmer than the left outlet?  | --  | System OK  | Go to Step 6  | 
6  | Inspect the door/actuator for the proper mounting or movement. Do the actuators operate correctly?  | --  | Go to Step 8  | Go to Step 7  | 
7  | Repair the actuator or door so that it operates correctly. Is the repair complete?  | --  | Go to Step 9  | --  | 
8  | Recover and recharge the A/C system. Refer to Refrigerant Recovery and Recharging in Heating, Ventilation and Air Conditioning. Does the system operate correctly?  | --  | Go to Step 9  | --  | 
9  | Confirm proper operation of the system. Does the system operate correctly?  | --  | System OK  | --  |