Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
DEFINITION: The blower does not operate in any mode.  | ||||
1  | 
 Is voltage greater than the specified value?  | 10.5 V  | Go to Step 2  | Go to Step 7  | 
2  | Ignition OFF, measure resistance of CKT 350 (BLK). Is resistance measured within the specified range?  | 0 ohms  | Go to Step 3  | Go to Step 8  | 
3  | 
 Is votlage measured greater than the value?  | 9 V  | Go to Go to Step 4  | Go to Step 5  | 
4  | 
 Is the voltage measured less than the value?  | 3 V  | Go to Step 6  | Go to Step 5  | 
5  | Inspect CKT 754(GRY/BLK) for a short to ground. Was a short condition repaired in CKT 754(GRY/BLK)?  | --  | Go to Step 12  | Go to Step 9  | 
6  | Measure voltage between terminals A and B of the blower motor. Is the votlage measured greater than the value?  | 10.5 V  | Go to Step 10  | Go to Step 11  | 
7  | Inspect CKT 1340 (ORN) for an open or a short to ground. Was a wiring fault located and repaired on CKT 1340 (ORN)?  | --  | Go to Step 12  | --  | 
8  | Repair the wire fault in the CKT 350 (BLK) between the blower control module and blower motor. Is the repair complete?  | --  | Go to Step 12  | --  | 
9  | Replace the instrument panel intergration module. Refer to Body Control Module Replacement Is the repair complete?  | --  | Go to Step 12  | --  | 
10  | Replace the blower motor. Refer to Blower Motor and Fan Replacement Is the repair complete?  | --  | Go to Step 12  | --  | 
11  | Replace the blower control module. Refer to Blower Motor Control Module Replacement Is the repair complete?  | --  | Go to Step 12  | --  | 
12  | Confirm proper operation of the blower motor. Is the blower motor operating correctly?  | --  | System OK  | --  |