- If a new HVAC module is being installed, add the specified amount of PAG
oil to the evaporator core. Refer to 
Refrigerant System Capacities 
 .
 
Notice: Refer to Fastener Notice in the Preface section.
- Install the HVAC module studs. 
 
Tighten
Tighten the studs to 4 N·m (35 lb in).
- Install new air inlet, drain and plumbing
seals to the HVAC module.
 
Important: Ensure that the cut-outs on the dash-mat
are properly aligned so that the drain and plumbing seals are seated directly against
the cowl and the air inlet seal is seated directly against the dash-mat.
The opening in the dash-mat for the HVAC module drain should be aligned so that the
drain opening in the cowl is approximately centered in the dash-mat opening; allowing
ample room for the module drain seal to fully seat against the cowl.
- Inspect the dash-mat for proper alignment to the cowl. Align if necessary.
 
Important: Spray a light coat of 3M™ P/N 08877
Silicone Lubricant Plus or equivalent onto the HVAC module heater cover to aid in
the installation process.
Notice: Do not force the HVAC module between upper I/P and lower I/P cross vehicle beams.
Damage to the HVAC module can result.
- Install the HVAC module into the vehicle.
 
- Reposition the center console wire harness and the corresponding electrical
connectors rearward of the lower tie bar.
 
- Install the recirculation housing to the HVAC module.
 
- Install the recirculation housing retaining
screws.
 
Tighten
Tighten the screws to 1.6 N·m (14 lb in).
- Connect the HVAC module wiring harness to the recirculation housing.
 
- Connect the recirculation actuator electrical
connector.
 
- Tighten the front LH recirculation housing
retaining screw.
 
Tighten
Tighten the screw to 1.6 N·m (14 lb in).
Important: If necessary, gently rotate the HVAC module
forward to engage the HVAC module studs through the corresponding holes on the cowl.
- Align the following components to the corresponding
openings on the cowl:
 
| •  | The heater core block fitting | 
 
| •  | The evaporator block fitting | 
 
- Install the bolts retaining the HVAC module
to the upper I/P cross vehicle beam.
 
Tighten
Tighten the bolts to 5 N·m (44 lb in).
Important: To prevent possible water leaks or wind/road
noise from entering the vehicle passenger compartment, do not reuse the old HVAC module
retaining and sealing nuts.
- Install new HVAC module retaining and sealing nuts.
 
Tighten
Tighten the nuts to 10 N·m (89 lb in).
- Install the blower motor to the HVAC module.
 
- Install the blower motor retaining screws.
 
Tighten
Tighten the screws to 1.6 N·m (14 lb in).
- Connect the blower motor electrical connector.
 
- Install the defroster duct to the HVAC module.
 
- Install the defroster duct retaining screws.
 
Tighten
Tighten the screws to 10 N·m (89 lb in).
- Install the right floor air outlet duct.
 
- Install the floor air outlet duct retaining
screws.
 
Tighten
Tighten the screws to 1.6 N·m (14 lb in).
- Install the knee bolster bracket. Refer to 
Passenger Knee Bolster Bracket Replacement 
 in Instrument Panel, Gages and
Console.
 
- Install the lower outlet duct to the side window defogger.
 
- Connect the lower outlet duct on the side window defogger to the defroster
duct.
 
- Connect the defogger lower outlet duct to
the knee bolster bracket.
 
- Connect the defogger upper outlet duct to the defogger lower outlet duct. 
 
- Install the retainers to the defogger upper
outlet duct.
 
- Install the left rear floor air outlet duct.
 
- Install the floor air outlet duct retaining
screws.
 
Tighten
Tighten the screws to 1.6 N·m (14 lb in).
- Install the air outlet duct.
 
- Connect the left floor air outlet duct to the left rear floor air outlet
duct.
 
- Install the retainer securing the left floor
air outlet duct to the lower I/P beam.
 
- Connect the window defogger lower outlet duct to the defroster duct.
 
- Install the defogger lower outlet duct retainer.
 
- Install the screw that secures the HUD to the steering column bracket.
 
Tighten
Tighten the screw to 3 N·m (27 lb in).
- Install the HUD retaining nuts.
 
Tighten
Tighten the nuts to 5 N·m (44 lb in).
- Connect
the HUD electrical connector.
 
- Connect the defogger upper outlet duct.
 
- Install the retainers to the upper defogger
duct.
 
- Install the I/P assembly. Refer to 
Instrument Panel Carrier Replacement 
 in Instrument Panel, Gages and Console.
 
Important: Ensure that the evaporator drain tube is
fully seated to the HVAC module.
- Install the evaporator drain tube  (1) to the HVAC module.
 
- Connect engine wire harness electrical connector.
 
- Install the engine wire harness bracket bolt.
 
Tighten
Tighten the bolt to 10 N·m (89 lb ft).
- Install the heater pipe assembly . Refer to 
Heater Pipes Replacement 
 .
 
- Fill the cooling system. Refer to 
Cooling System Draining and Filling 
 in Engine Cooling.
 
- Evacuate and recharge the A/C system. Refer to 
Refrigerant Recovery and Recharging 
 .
 
- Leak test the fittings of the component using J 39400-A 
 .