| Table 1: | A/C Performance Table | 
This test measures the operating efficiency of the A/C system under the following conditions:
| • | The current ambient air temperature | 
| • | The current relative humidity | 
| • | The high side pressure of the A/C system | 
| • | The low side pressure of the A/C system | 
| • | The temperature of the air being discharged into the passenger compartment | 
The numbers below refer to the step numbers on the diagnostic table.
This step determines if the A/C system has at least the minimum refrigerant charge required to operate the system without damage.
This step measures the performance of the A/C system.
This step is to allow for vehicle variations as well as high ambient temperatures.
Step  | Action  | Values  | Yes  | No  | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 
 Important: 
  | ||||||||||||||||||||||||||
 
 
 
 
 
 Are both the low side and high side pressures within the specified value?  | Greater than 16°C (60°F) - 345 kPa (50 psi) Greater than 24°C (75°F) - 483 kPa (70 psi) Greater than 33°C (90°F) - 690 kPa (100 psi)  | Go to Step 2  | Go to Leak Testing  | |||||||||||||||||||||||
 Important: Record the relative humidity and the ambient air temperature at the time of the test. 
 
 
 
 
 
 
 
 Important: Press the RESET button, before using the print function of the J 43600 . 
 
 
 Does all the data recorded fall within the specified ranges of the table below?  | --  | Go to Step 8  | Go to Step 3  | |||||||||||||||||||||||
If the pressures and temperatures recorded do not fall within the specified ranges: 
 Does all the data recorded fall within the specified ranges of the table below?  | --  | Go to Step 8  | Go to Step 4  | |||||||||||||||||||||||
4  | Do the high and low side pressures fall within the specified ranges, but the panel outlet temperature do not?  | --  | Go to Step 5  | |||||||||||||||||||||||
5  | Is the low side pressure greater than the specified range, but the high side pressure within or less than the specified range?  | --  | Go to Step 6  | |||||||||||||||||||||||
6  | Are the low and high side pressures both greater than the specified ranges?  | --  | Go to Step 7  | |||||||||||||||||||||||
7  | Is the high side pressure greater than the specified range, but the low side pressure is within or less than the specified range?  | --  | Go to Step 8  | |||||||||||||||||||||||
8  | Operate the system in order to verify the test results. Did you find the same results?  | --  | System OK  | Go to Symptoms - HVAC Systems - Automatic in HVAC Systems - Automatic  | ||||||||||||||||||||||
Ambient Air Temperature  | Relative Humidity  | Service Port Pressure  | Maximum Left Center Discharge Air Temperature  | |
|---|---|---|---|---|
Low Side  | High Side  | |||
13-18°C (55-65°F)  | 0-100%  | 175-195 kPa (25-29 psi)  | 1820-2070 kPa (264-301 psi)  | 6°C (43°F)  | 
18-24°C (65-75°F)  | Below 40%  | 175-219 kPa (25-32 psi)  | 1770-2010 kPa (256-292 psi)  | 8°C (47°F)  | 
Above 40%  | 175-236 kPa (25-35 psi)  | 1870-2070 kPa (271-301 psi)  | 9°C (49°F)  | |
24-29°C (75-85°F)  | Below 35%  | 175-239 kPa (25-35 psi)  | 1890-2050 kPa (274-298 psi)  | 10°C (50°F)  | 
35-60%  | 177-246 kPa (25-36 psi)  | 1920-2060 kPa (278-299 psi)  | 11°C (52°F)  | |
Above 60%  | 184-262 kPa (26-38 psi)  | 1940-2080 kPa (281-302 psi)  | 12°C (54°F)  | |
29-35°C (85-95°F)  | Below 30%  | 188-261 kPa (27-38 psi)  | 1960-2130 kPa (284-310 psi)  | 12°C (54°F)  | 
30-50%  | 196-274 kPa (28-40 psi)  | 1970-2110 kPa (285-307 psi)  | 13°C (56°F)  | |
Above 50%  | 206-294 kPa (29-43 psi)  | 1980-2080 kPa (287-302 psi)  | 15°C (59°F)  | |
35-41°C (95-105°F)  | Below 20%  | 208-278 kPa (30-41 psi)  | 2060-2220 kPa (299-323 psi)  | 13°C (56°F)  | 
20-40%  | 214-294 kPa (31-43 psi)  | 2060-2180 kPa (299-317 psi)  | 15°C (59°F)  | |
Above 40%  | 227-309 kPa (32-45 psi)  | 2040-2130 kPa (296-310 psi)  | 16°C (61°F)  | |
41-46°C (105-115°F)  | Below 20%  | 230-298 kPa (33-44 psi)  | 2170-2300 kPa (314-334 psi)  | 14°C (58°F)  | 
Above 20%  | 238-316 kPa (34-46 psi)  | 2140-2230 kPa (310-324 psi)  | 16°C (61°F)  | |
46-49°C (115-120°F)  | Below 30%  | 258-319 kPa (37-47 psi)  | 2220-2300 kPa (322-334 psi)  | 16°C (61°F)  |