Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | Did you review the HVAC operation and perform the necessary inspections?  | --  | Go to Step 2  | |
2  | 
 Does the voltage measured equal the specified value?  | B+  | Go to Step 3  | Go to Step 4  | 
3  | 
 Does the voltage measured equal the specified value?  | B+  | Go to Step 5  | Go to Step 6  | 
4  | Replace the heater A/C control assembly. Refer to Control Assembly Replacement . Is the repair complete?  | --  | System OK  | --  | 
5  | Replace the blower resistor assembly. Refer to Blower Motor Resistor Replacement . Is the repair complete?  | --  | System OK  | --  | 
6  | Repair the open in CKT 60 between the heater A/C assembly and the blower resistor assembly. Refer to Wiring Repairs in Wiring Systems. Is the repair complete?  | --  | System OK  | --  |