Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | Did you review the HVAC operation and perform the necessary inspections?  | --  | Go to Step 2  | |
2  | Replace the blower motor relay with a known good relay. Does the blower motor operate properly?  | --  | Go to Step 3  | Go to Step 4  | 
3  | Replace the blower motor relay. Is the repair complete?  | --  | System OK  | --  | 
4  | Turn the ignition to the OFF position. Unplug the blower motor relay. Check for power at female terminal 86 of blower motor relay receptical. Is power present?  | 12V  | Go to Step 5  | Go to Step 6  | 
5  | Repair the short to B+ in the blower motor High circuit between the heater A/C control assembly and the blower motor relay. Refer to Wiring Repairs in wiring systems. Is the repair complete?  | --  | System OK  | --  | 
6  | Check for power at female terminal 87A of the blower motor relay receptical. Is power present?  | --  | Go to Step 7  | Go to Step 9  | 
7  | Disconnect the blower resistor assembly connector. Check for power at terminals A,B,C and D of blower resistor assembly connector. Is power present ?  | 12V  | Go to Step 8  | Go to Step 11  | 
8  | Repair short to B+ on the circuit that was found to have power between the heater A/C control assembly and the blower resistor assembly. Refer to Wiring Repairs in wiring systems. Is the repair complete?  | --  | System OK  | --  | 
9  | Disconnect blower motor connector. Check terminal B of Blower Motor feed circuit for power. Is power present?  | 12V  | Go to Step 10  | System OK  | 
10  | Repair short to B+ in the blower motor power feed circuit between the blower relay and the blower motor. Refer to Wiring Repairs in wiring systems. Is the repair complete?  | --  | System OK  | --  | 
11  | Repair short to B+ in the blower resistor circuit between the blower resistor assembly and the blower relay. Refer to Wiring Repairs in wiring systems. Is the repair complete?  | --  | System OK  | --  |