Step  | Action  | Yes  | No  | 
|---|---|---|---|
Schematic Reference: Interior Lights Schematics  | |||
1  | Did you perform the Lighting Systems Diagnostic System Check?  | Go to Step 2  | |
2  | Verify that the IP compartment lamp is inoperative. Does the IP compartment lamp operate normally?  | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems  | Go to Step 3  | 
3  | Inspect the bulb for an open filament. Was a problem found?  | Go to Step 9  | Go to Step 4  | 
4  | Test the inadvertent power courtesy lamps supply voltage circuit for an open, high resistance, or short to ground. Refer to Circuit Testing in Wiring Systems. Was a problem found?  | Go to Step 6  | Go to Step 5  | 
5  | Test for an open or high resistance in the ground circuit. Refer to Circuit Testing in Wiring Systems. Was a problem found?  | Go to Step 7  | Go to Step 8  | 
6  | Repair the open, high resistance, or short to ground in the inadvertent power courtesy lamps supply voltage circuit. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair?  | Go to Step 10  | --  | 
7  | Repair the open or high resistance in the ground circuit. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair?  | Go to Step 10  | --  | 
8  | Replace the IP compartment lamp assembly. Refer to Instrument Panel Storage Compartment Lamp Replacement . Did you complete the repair?  | Go to Step 10  | --  | 
9  | Replace the IP compartment lamp bulb. Did you complete the repair?  | Go to Step 10  | --  | 
10  | Operate the system in order to verify the repair. Did you correct the condition?  | System OK  | Go to Step 3  |