| Table 1: | A/C Performance Table | 
| Table 2: | A/C Performance Table With Rear A/C | 
This test measures the operating efficiency of the A/C system under the following conditions:
| • | The current ambient air temperature | 
| • | The current relative humidity | 
| • | The high side pressure of the A/C system | 
| • | The low side pressure of the A/C system | 
| • | The temperature of the air being discharged into the passenger compartment | 
The numbers below refer to the step numbers on the diagnostic table.
This step determines if the A/C system has at least the minimum refrigerant charge required to operate the system without damage.
This step measures the performance of the A/C system.
This step is to allow for vehicle variations as well as high ambient temperatures.
Step  | Action  | Values  | Yes  | No  | ||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 
 Important: 
  | ||||||||||||||||||||||||||||
 Are both the low side and high side pressures within the specified value?  | More than 16°C (60°F), 345 kPa (50 psi) More than 24°C (75°F), 483 kPa (70 psi) More than 33°C (90°F), 690 kPa (100 psi)  | Go to Step 2  | Go to Leak Testing  | |||||||||||||||||||||||||
 Important: Record the relative humidity and the ambient air temperature at the time of the test. 
 
 
 
 
 
 
 
 
 Important: Press the RESET button, before using the print function of the J 43600 . 
 
 
 Does all the data recorded fall within the specified ranges of the A/C performance table?  | --  | Go to Step 4  | Go to Step 3  | |||||||||||||||||||||||||
If the pressures and temperatures recorded do not fall within the specified ranges: 
 Does all the data recorded fall within the specified ranges of the A/C performance table?  | --  | Go to Step 8  | Go to Step 4  | |||||||||||||||||||||||||
4  | Do the high and low side pressures fall within the specified ranges, but the outlet temperatures do not?  | --  | Go to Step 5  | |||||||||||||||||||||||||
5  | Is the low side pressure greater than the specified range, but the high side pressure within or less than the specified range?  | --  | Go to Step 6  | |||||||||||||||||||||||||
6  | Are the low and high side pressures both greater than the specified ranges?  | --  | Go to Step 7  | |||||||||||||||||||||||||
7  | Is the high side pressure greater than the specified range, but the low side pressure is within or less than the specified range?  | --  | Go to Step 8  | |||||||||||||||||||||||||
8  | Operate the system in order to verify the test results. Did you find the same results?  | --  | System OK  | |||||||||||||||||||||||||
Ambient Air Temperature  | Relative Humidity  | Service Port Pressure  | Maximum Left Center Discharge Air Temperature  | |
|---|---|---|---|---|
Low Side  | High Side  | |||
13-18°C (55-65°F)  | 0-100%  | 131-172 kPa (19-25 psi)  | 1000-1276 kPa (135-175 psi)  | 4°C (40°F)  | 
19-24°C (66-75°F)  | Below 40%  | 165-207 kPa (24-30 psi)  | 1103-1379 kPa (160-200 psi)  | 7°C (44°F)  | 
Above 40%  | 165-207 kPa (24-30 psi)  | 1172-1448 kPa (170-210 psi)  | 7°C (44°F)  | |
25-29°C (76-85°F)  | Below 35%  | 179-221 kPa (26-32 psi)  | 1310-1586 kPa (190-230 psi)  | 8°C (47°F)  | 
35-60%  | 200-241 kPa (29-35 psi)  | 1344-1620 kPa (195-235 psi)  | 10°C (50°F)  | |
Above 60%  | 207-248 kPa (30-36 psi)  | 1344-1620 kPa (195-235 psi)  | 11°C (51°F)  | |
30-35°C (86-95°F)  | Below 30%  | 234-276 kPa (34-40 psi)  | 1620-1896 kPa (235-275 psi)  | 12°C (54°F)  | 
30-50%  | 262-303 kPa (38-44 psi)  | 1793-2068 kPa (260-300 psi)  | 16°C (60°F)  | |
Above 50%  | 276-324 kPa (40-47 psi)  | 1793-2068 kPa (260-300 psi)  | 16°C (60°F)  | |
36-41°C (96-105°F)  | Below 20%  | 262-317 kPa (38-46 psi)  | 1793-2068 kPa (260-300 psi)  | 15°C (59°F)  | 
20-40%  | 255-310 kPa (37-45 psi)  | 1586-1862 kPa (230-270 psi)  | 14°C (57°F)  | |
Above 40 %  | 296-352 kPa (43-51 psi)  | 1999-2275 kPa (290-330 psi)  | 17°C (63°F)  | |
42-46°C (106-115°F)  | Below 20%  | 262-317 kPa (38-46 psi)  | 1758-2034 kPa (255-295 psi)  | 15°C (59°F)  | 
Above 20%  | 269-324 kPa (39-47 psi)  | 1758-2034 kPa (255-295 psi)  | 16°C (60°F)  | |
47-49°C (116-120°F)  | Below 30%  | 296-352 kPa (43-51 psi)  | 1931-2206 kPa (280-320 psi)  | 18°C (64°F)  | 
Ambient Air Temperature  | Relative Humidity  | Service Port Pressure  | Maximum Rear Discharge Air Temperature  | |
|---|---|---|---|---|
Low Side  | High Side  | |||
13-18°C (55-65°F)  | 0-100%  | 131-172 kPa (19-25 psi)  | 1000-1276 kPa (135-175 psi)  | 4°C (40°F)  | 
19-24°C (66-75°F)  | Below 40%  | 165-207 kPa (24-30 psi)  | 1103-1379 kPa (160-200 psi)  | 7°C (44°F)  | 
Above 40%  | 165-207 kPa (24-30 psi)  | 1172-1448 kPa (170-210 psi)  | 7°C (44°F)  | |
25-29°C (76-85°F)  | Below 35%  | 179-221 kPa (26-32 psi)  | 1310-1586 kPa (190-230 psi)  | 8°C (47°F)  | 
35-60%  | 200-241 kPa (29-35 psi)  | 1344-1620 kPa (195-235 psi)  | 10°C (50°F)  | |
Above 60%  | 207-248 kPa (30-36 psi)  | 1344-1620 kPa (195-235 psi)  | 11°C (51°F)  | |
30-35°C (86-95°F)  | Below 30%  | 234-276 kPa (34-40 psi)  | 1620-1896 kPa (235-275 psi)  | 12°C (54°F)  | 
30-50%  | 262-303 kPa (38-44 psi)  | 1793-2068 kPa (260-300 psi)  | 16°C (60°F)  | |
Above 50%  | 276-324 kPa (40-47 psi)  | 1793-2068 kPa (260-300 psi)  | 16°C (60°F)  | |
36-41°C (96-105°F)  | Below 20%  | 262-317 kPa (38-46 psi)  | 1793-2068 kPa (260-300 psi)  | 15°C (59°F)  | 
20-40%  | 255-310 kPa (37-45 psi)  | 1586-1862 kPa (230-270 psi)  | 14°C (57°F)  | |
Above 40%  | 296-352 kPa (43-51 psi)  | 1999-2275 kPa (290-330 psi)  | 17°C (63°F)  | |
42-46°C (106-115°F)  | Below 20%  | 262-317 kPa (38-46 psi)  | 1758-2034 kPa (255-295 psi)  | 15°C (59°F)  | 
Above 20%  | 269-324 kPa (39-47 psi)  | 1758-2034 kPa (255-295 psi)  | 16°C (60°F)  | |
47-49°C (116-120°F)  | Below 30%  | 296-352 kPa (43-51 psi)  | 1931-2206 kPa (280-320 psi)  | 18°C (64°F)  |