Step  | Action  | Normal Result(s)  | Abnormal Result(s)*  | 
|---|---|---|---|
1  | Visually inspect the Battery Hydrometer.  | Battery Hydrometer displays a green eye.  | |
2  | Visually inspect Battery cables.  | Battery cables are clean and tightly connected.  | Refer to Battery Cable  | 
3  | Inspect Fuse 6, Crank Fuse 8, Gauges Fuse 4 and Fusible Link.  | Fuses are not open.  | Repair source of overload and Replace Fuse.  | 
4  | Inspect all grounds.  | All grounds are clean and tightly connected.  | Clean and tighten grounds.  | 
5  | Inspect Starter Motor and Starter Solenoid.  | Both Starter Motor and Starter Solenoid are properly mounted and Starter Solenoid terminals S and B are clean and tight.  | Ensure proper mounting and clean and tighten terminals.  | 
6  | Move the Ignition Switch from the Off position to the Run position.  | BAT Indicator lamp turns on, engine does not run.  | Refer to Volt/Charge Indicator Inoperative .  | 
7  | Move the Ignition Switch to the Start position and then slowly release.  | Starter motor runs, the Engine starts, and the BAT Indicator Lamp turns off  | Refer to Starter Solenoid Does Not Click .  | 
8  | Allow Engine to run for approximately 5-7 minutes. Measure voltage at the Battery terminals.  | Voltage reading of 13-16 volts.  | Refer to Battery Is Undercharged or Overcharged .  | 