Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | Was the Garage Door Opener System Check performed?  | --  | Go to Step 2  | |
2  | Check courtesy fuse 3 at the I/P fuse block. Is the fuse functional?  | --  | Go to Step 4  | Go to Step 3  | 
3  | Locate source of overload and replace courtesy fuse 3 at the I/P fuse block. Is the repair complete?  | --  | --  | |
4  | 
 Does C1 and/or C2 have loose, improperly seated terminals or poor retention of the locking tab?  | --  | Go to Step 5  | Go to Step 6  | 
5  | 
 Is the repair complete?  | --  | --  | |
6  | 
 Is there continuity?  | --  | Go to Step 8  | Go to Step 7  | 
7  | Locate and repair open in CKT 40 (ORN) between console and I/P fuse block. Is the repair complete?  | --  | --  | |
8  | 
 Is there continuity?  | --  | Go to Step 10  | Go to Step 9  | 
9  | Locate and repair open in CKT 1382 (PPL/WHT) between console and I/P. Is the repair complete?  | --  | --  | |
10  | Check continuity on CKT 1350 (BLK) from console to G400. Is the wire functional?  | --  | Go to Step 12  | Go to Step 11  | 
11  | Locate and repair open in CKT 1350 (BLK) between console and G400. Is the repair complete?  | --  | --  | |
12  | Replace the Garage Door Opener module. Refer to Garage Door Opener Module Replacement . Is the repair complete?  | --  | --  |