Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | Did you perform the Power Door Locks System Check?  | --  | Go to Step 2  | |
2  | 
 Does the test lamp light?  | --  | Go to Step 3  | Go to Step 6  | 
3  | Is the lock function inoperative by the liftgate lock/unlock switch?  | --  | Go to Step 5  | Go to Step 4  | 
4  | 
 Does the test lamp light?  | --  | Go to Step 7  | Go to Step 6  | 
5  | Repair the open in CKT 195 (LT BLU) between the liftgate lock/unlock release switch and splice S232. Is the repair complete?  | --  | --  | |
6  | Use a test lampJ 35616-200 in order to backprobe CKT 640 (ORN) cavity D at the liftgate lock/unlock release switch to ground. Does the test lamp light?  | --  | Go to Step 8  | Go to Step 9  | 
7  | Repair the open in CKT 194 (WHT) between the liftgate lock/unlock release switch and splice S231. Is the repair complete?  | --  | --  | |
8  | Replace the liftgate lock/unlock release switch. Is the repair complete?  | --  | --  | |
9  | Repair the open in CKT 640 (ORN) between the instrument panel fuse block and the liftgate lock/unlock release switch. Is the repair complete?  | --  | --  |