Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | Did you perform the Power Door Locks System Check?  | --  | Go to Step 2  | |
2  | Use a test lampJ 35616-200 in order to backprobe CKT 640 (ORN) cavity B or cavity F at the inoperative door lock switch to ground. Does the test lamp light?  | --  | Go to Step 4  | Go to Step 3  | 
3  | Repair the open in CKT 640 (ORN) between the inoperative door lock switch and splice S223. Is the repair complete?  | --  | --  | |
4  | 
 Does the test lamp light?  | --  | Go to Step 6  | Go to Step 5  | 
5  | Replace the inoperative door lock switch. Is the repair complete?  | --  | --  | |
6  | 
 Does the test lamp light?  | --  | Go to Step 11  | Go to Step 5  | 
7  | Operate the inoperative door lock switch in both the LOCK and the UNLOCK positions. Is the LOCK position still inoperative?  | --  | Go to Step 8  | Go to Step 9  | 
8  | Repair the open in CKT 195 (LT BLU) between the inoperative door lock switch and splice S232. Is the repair complete?  | --  | --  | |
9  | Operate the inoperative door lock switch in both the LOCK and the UNLOCK position. Is the UNLOCK position still inoperative?  | --  | Go to Step 10  | Go to Step 11  | 
10  | Repair the open in CKT 194 (WHT) between the inoperative door lock switch and splice S231. Is the repair complete?  | --  | --  | |
11  | Operate the inoperative door lock switch in both the LOCK and the UNLOCK positions. Are both the LOCK and the UNLOCK positions still inoperative?  | --  | Go to Step 5  | Go to Step 7  |