Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | Did you perform the Instrument Cluster Diagnostic System Check?  | --  | Go to Step 2  | |
2  | Verify the fault is present. Does the system operate normally?  | --  | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems  | Go to Step 3  | 
3  | 
 Important: There is a flat band in the gauge where the engine temp is between 190°F (88°C) and 220°F (104°C) and gauge stays at 200°F (93°C). 
 Is the temperature on the scan tool and the temperature on the gauge approximately the same outside the flat band?  | Approximately 200°F (93°C) @ steady state  | Go to Step 4  | Go to Step 5  | 
4  | 
 Does the gauge reading properly?  | --  | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems  | Go to Step 5  | 
5  | Replace the instrument cluster. Refer to Instrument Cluster Replacement . Did you complete the replacement?  | --  | Go to Step 6  | --  | 
6  | Operate the system in order to verify the repair. Did you correct the condition?  | --  | System OK  | Go to Step 3  |