Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | Did you perform the Instrument Cluster Diagnostic System Check?  | --  | Go to Step 2  | |
2  | Verify the volt gauge is inaccurate or inoperative. Does the volt gauge operate normally?  | --  | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems  | Go to Step 3  | 
3  | 
 Does the cluster and the DMM display the approximately the same values?  | --  | Go to Step 5  | Go to Step 4  | 
4  | Replace the instrument cluster. Refer to Instrument Cluster Replacement Did you complete the replacement?  | --  | Go to Step 5  | --  | 
5  | Operate the system in order to verify the repair. Did you correct the condition?  | --  | System OK  | Go to Step 3  |