Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | Did you review the Stationary Windows Description and perform the necessary inspections?  | --  | Go to Step 2  | Go to Symptoms  | 
2  | Disconnect the RR defog fuse. Did the rear window defogger grid turn off?  | --  | Go to Step 4  | Go to Step 3  | 
3  | Locate and repair short to power in CKT 1093. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair?  | --  | Go to Step 7  | --  | 
4  | 
 Did the rear window defogger grid turn off?  | --  | Go to Step 6  | Go to Step 5  | 
5  | Locate and repair short to power in CKT 293. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair?  | --  | Go to Step 7  | --  | 
6  | Replace the Heater and A/C Control Module. Refer to Control Assembly Replacement in Heating, Ventilation and Air Conditioning. Did you complete the replacement?  | --  | Go to Step 7  | --  | 
7  | Operate the system in order to verify the repair. Did you correct the condition?  | --  | System OK  | Go to Step 2  |