Danger: Before working on any high voltage system, be sure to wear the following Personal Protection Equipment:
|    •  | Safety glasses with appropriate side shields when within 50 feet of the vehicle, either indoors or outdoors | 
 
|    •  | Certified and up-to-date Class "0" Insulation gloves rated at 1000V with leather protectors | 
 
|       -  |  Visually and functionally inspect the gloves before use. | 
 
|       -  |  Wear the Insulation gloves at all times when working with the high voltage battery assembly, whether the system is energized or not. | 
 
Failure to follow the procedure exactly as written may result in serious injury or death.
Caution: Refer to Test Probe Caution in the Preface section.
The following procedure measures the voltage at a selected point in a circuit.
- Disconnect the electrical harness connector for the circuit being tested, if necessary.
 
- Enable the circuit and/or system being tested. Use the following methods:
 
| •  | Turn ON the ignition, with the engine OFF. | 
 
| •  | Turn ON the circuit and/or system with a scan tool in Output Controls. | 
 
| •  | Turn ON the switch for the circuit and/or system being tested. | 
 
- Select the V (AC) or V (DC) position on the DMM.
 
- Connect the negative lead of the DMM to a good ground. 
 
- Connect the positive lead of the DMM to the point of the circuit to be tested. 
 
- The DMM displays the voltage measured at that point.