| • | The transmission control module (TCM) detects that the analog-to-digital (A/D) value of the transmission fluid temperature (TFT) sensor signal is less than 10 for 5 minutes continuously after 1 occurrence of this detection. A/D value 10: 24 Mv | 
| • | The TCM does not detect pass criteria achieved. | 
| • | TCM will request the illumination of hold lamp and store DTC when TCM detects a failure on the first ignition cycle | 
| • | TCM judges the temperature of the transmission fluid is 200°C (392°F) | 
| • | No lockup control | 
| • | No 4th gear | 
| • | No self-learning control | 
| • | No timing solenoid control N-D | 
| • | The TCM turns OFF the hold lamp when no further failures are detected on the next ignition cycles. | 
| • | The scan tool can clear the DTC from the TCM history. | 
| • | The TCM clears the DTC from the TCM history memory after 40 consecutive ignition cycles without fault. | 
| • | The TCM detects the temperature of the transmission fluid is between 0°C (32°F) and 150°C (302°F) for 10 seconds continuously. | 
| • | Wiring harness or connector between TFT sensor and TCM | 
| • | TFT sensor | 
| • | TCM | 
Step  | Action  | Values  | Yes  | No  | 
|---|---|---|---|---|
1  | 
 Is the hold lamp ON?  | --  | Go to Step 2  | Go to Step 4  | 
2  | 
 Is DTC P0712 displayed?  | --  | Go to Step 3  | Go to Step 4  | 
3  | 
 Is the measurement within the specified values?  | 10°C (50°F) 5.80-7.09 kohms 110°C (230°F) 0.231-0.263 kohms  | Go to Step 5  | Go to Step 6  | 
4  | Repair the temporary connection failure of the connector. Refer to Wiring Harness and Connector Inspection Diagnosis . Did you complete the repair?  | --  | System OK  | --  | 
5  | 
 Is the connection condition OK?  | --  | Go to Step 7  | Go to Step 4  | 
6  | 
 Is the measurement within the specified values?  | 10°C (50°F) 5.80-7.09 kohms 110°C (230°F) 0.231-0.263 kohms  | Go to Step 8  | Go to Step 9  | 
7  | 
 Is DTC displayed?  | --  | Go to Step 1  | System OK  | 
8  | 
 Is the condition OK?  | --  | System OK  | Go to Step 4  | 
9  | 
 Is the problem found?  | --  | Go to Step 11  | Go to Step 10  | 
10  | 
 Is the condition OK?  | --  | System OK  | Go to Step 4  | 
11  | Replace the TFT sensor. Refer to Transmission Fluid Temperature Sensor Inspection . Did you complete the replacement?  | --  | System OK  | --  | 
| • | The transmission control module (TCM) detects that the analog-to-digital (A/D) value of the transmission fluid temperature (TFT) sensor signal is less than 10 for 5 minutes continuously after 1 occurrence of this detection. A/D value 10: 24 Mv | 
| • | The TCM does not detect pass criteria achieved. | 
| • | TCM will request the illumination of malfunction indicator lamp (MIL) and store DTC when TCM detects a failure on the first ignition cycle | 
| • | TCM judges the temperature of the transmission fluid is 200°C (392°F) | 
| • | No lockup control | 
| • | No 4th gear | 
| • | No self-learning control | 
| • | No timing solenoid control N-D | 
| • | The TCM turns OFF the MIL when no further failures are detected on the next ignition cycles. | 
| • | The scan tool can clear the DTC from the TCM history. | 
| • | The TCM clears the DTC from the TCM history memory after 40 consecutive ignition cycles without fault. | 
| • | The TCM detects the temperature of the transmission fluid is between 0°C (32°F) and 150°C (302°F) for 10 seconds continuously. | 
| • | Wiring harness or connector between TFT sensor and TCM | 
| • | TFT sensor | 
| • | TCM | 
Step  | Action  | Values  | Yes  | No  | 
|---|---|---|---|---|
1  | 
 Is the malfunction indicator lamp (MIL) ON?  | --  | Go to Step 2  | Go to Step 4  | 
2  | 
 Is DTC P0712 displayed?  | --  | Go to Step 3  | Go to Step 4  | 
3  | 
 Is the measurement within the specified values?  | 10°C (50°F) 5.80-7.09 kohms 110°C (230°F) 0.231-0.263 kohms  | Go to Step 5  | Go to Step 6  | 
4  | Repair the temporary connection failure of the connector. Refer to Wiring Harness and Connector Inspection Diagnosis . Did you complete the repair?  | --  | System OK  | --  | 
5  | 
 Is the connection condition OK?  | --  | Go to Step 7  | Go to Step 4  | 
6  | 
 Is the measurement within the specified values?  | 10°C (50°F) 5.80-7.09 kohms 110°C (230°F) 0.231-0.263 kohms  | Go to Step 8  | Go to Step 9  | 
7  | 
 Is DTC displayed?  | --  | Go to Step 1  | System OK  | 
8  | 
 Is the condition OK?  | --  | System OK  | Go to Step 4  | 
9  | 
 Is the problem found?  | --  | Go to Step 11  | Go to Step 10  | 
10  | 
 Is the condition OK?  | --  | System OK  | Go to Step 4  | 
11  | Replace the TFT sensor. Refer to Transmission Fluid Temperature Sensor Replacement . Did you complete the replacement?  | --  | System OK  | --  |